家园 AFPy用于肝癌诊断 远非没有争议。何况肿瘤筛查

The sensitivity and specificity of AFP varied widely, and this could not be entirely attributed to the threshold effect

of the different cutoff levels used.

------------------

(Am J Gastroenterol 2006;101:513–523)

Accuracy of Ultrasonography, Spiral CT, Magnetic Resonance, and Alpha-Fetoprotein in Diagnosing Hepatocellular Carcinoma: A Systematic Review

CME

Agostino Colli, M.D.,1 Mirella Fraquelli, M.D., Ph.D.,2 Giovanni Casazza, Ph.D.,3 Sara Massironi, M.D.,1

Alice Colucci, M.D.,1 Dario Conte, M.D.,2 and Piergiorgio Duca, M.D.3

1Department of Internal Medicine, Ospedale “A. Manzoni”, Lecco, 2Postgraduate School of Gastroenterology,

IRCCS Ospedale Maggiore, Milan, and 3Department of Clinical Sciences, Ospedale “L. Sacco”, Milan, Italy

BACKGROUND In patients with chronic liver disease, the accuracy of ultrasound scan (US), spiral computed AND AIM: omography (CT), magnetic resonance imaging (MRI), and alpha-fetoprotein (AFP) in diagnosing hepatocellular carcinoma (HCC) has never been systematically assessed, and present systematic review was aimed at this issue.

METHODS: Pertinent cross-sectional studies having as a reference standard pathological examinations of the explanted liver or resected segment(s), biopsies of focal lesion(s), nd/or a period of follow-up, were identified using MEDLINE, EMBASE, Cochrane Library, and CancerLit. Pooled sensitivity, specificity, and likelihood ratios (LR) were calculated using the random effect model. Summary receiver operating characteristic (SROC) curve and predefined subgroup analyses were made when indicated.

RESULTS: The pooled estimates of the 14 US studies were 60% (95% CI 44–76) for sensitivity, 97% (95% CI 95–98) for specificity, 18 (95% CI 8–37) for LR+, and 0.5 (95% CI 0.4–0.6) for LR; for the 10 CT studies sensitivity was 68% (95% CI 55–80), specificity 93% (95% CI 89–96), LR+ 6 (95% CI

3–12),and LR 0.4 (95% CI 0.3–0.6); for the nine MRI studies sensitivity was 81% (95% CI 70–91), specificity 85% (95%CI 77–93), LR+ 3.9 (95%CI 2–7), and LR 0.3 (95% CI 0.2–0.5). The sensitivity and specificity of AFP varied widely, and this could not be entirely attributed to the threshold effect of the different cutoff levels used.

CONCLUSIONS: US is highly specific but insufficiently ensitive to detect HCC in many cirrhotics or to support an

effective surveillance program. The operative characteristics of CT are comparable, whereas MRI is more sensitive. High-quality prospective studies are needed to define the actual diagnostic role of AFP.